SSPC-Paint 20: Level 2
Amount of zinc dust: from 77% to 85%
ISO 12944
Corrosion protection for C5-H
EN 13501-1
Fire reaction: B-s1, d0 class
Product reserved to professional users, according to the REACH Regulation.
Technical Documentation
Technical DataSheet 7K800 EN
Material Safety DataSheet 7K801 7101 EN
Material Safety DataSheet 7K802 9999 EN
Preparation and Application

Steel: blast clean the steel to Sa 2½ grade, according to ISO 8501-1. The roughness profile should be adjusted, depending on the thickness of the product to be applied. Remove powder residues and abrasive residues from surface. These indications are generic, applicable to several products and merely informative.